Ice and Snow Melting Systems - ANTALYA TURKEY OLESEN


Ice and Snow Melting Systems

  • Overview
  • Ice and Snow Melting Systems

    Efficient and safe
    We cannot control the weather but we do control the consequences.. Winter is a beautiful time,
    but it is hard work clearing snow and ice.
    HandyHeat offers a safe, efficient and economical system for melting ice and snow avoiding serious
    accidents. The ETO controller for ground snow melting, along with readings from temperature
    and moisture sensors, ensures economical control of snow melting for walkways, steps, ramps,
    parking and similar areas.
    Application
    HandyHeat Ice- and Snow melting systems may be used on nearly all kind of outdoor areas and
    surfaces, where Ice and snow may cause problems.
    Most common surfaces such as Tiles, concrete and asphalt is applicable.
    System components
    The DVT-30 heating cable and the ETO controller along with the ETOG sensor is a general purpose
    system, witch will cover from small to big surface installations.
    As a general purpose system for drains and gutters, the DVT-30 heating cable and the ETR/F-
    1447A (small systems) or the ETO (bigger systems) controller along with the ETOR sensor, covers
    most applications.

    Features
    HandyHeat ice and snow melting systems
    Keeps
    Driveways
    walkways
    Ramps
    Stairways
    Parking areas
    free of snow and ice.
    Prevent damage from Frozen Roofs, Gutters
    and Drains in the winter.
    Automatic Ice & Snow melting
    Time saving
    Energy efficient controller and sensors.
    Environmental safe, no need for salt.

    Technical data
    Supply voltage 230 VAC / 50 Hz
    DVT-20 20 Watt per linear metre
    DVT-30 30 Watt per linear metre
    Power per Square metre, 200 to 350
    Watt/m² on surface areas
    Power per metre gutter, 200 to 300
    Watt
    ETO controller
    3 output relays (volt-free contact)
    10A, 10A, 16A
    Temperature range 0/+5°C
    On/off differential 0.3°C
    Scale adjustment potentiometer for
    sensor calibration
    Built-in timer for manual snow melting
    1-6 hours
    Detection mode MOIST CONTROL:
    Position ON Moisture and temperature
    Position OFF only temperature
    Ramp with cable and snow and Ice detector
    before covering with concrete
    Gutter and drain with DVT-20 heating cable
    and ETOR Ice detector preventing icicles and
    possible damages of roof construction.


    PDF

x
Loading...